Trane Defrost Control Board LED Codes | Solve Common Issue!

If your Trane furnace is equipped with a defrost control board , you can use the LED codes to help troubleshoot any problems that may arise. The most common code is the “red flash” which indicates that the board is in defrost mode.

Other codes include the “green flash” which means that the furnace is operating normally, and the “amber flash” which indicates a problem with the igniter.

Trane Defrost Control Board LED Codes

Page Contents

Trane Defrost Control Board LED Codes

The Trane Defrost Control Board is a crucial component of HVAC systems that helps to regulate the defrost cycle, ensuring the efficient functioning of the system. The board is equipped with LED codes that allow troubleshooting and identification of issues that could arise during operation.

The codes and their meanings are as follows:

  • Steady Green LED – The system is operating normally.
  • Steady Red LED – The defrost control board has detected a fault and is in lockout mode.
  • Flashing Red LED – The sensor is not detecting proper temperature, indicating a possible faulty sensor or a wiring issue.
  • Flashing Green LED – The system is in defrost mode, and the board is actively monitoring the process.
  • Steady On – Power is present
  • Flashing Slowly – Normal operation
  • Flashing Rapidly – Defrost is active
  • Two Flashes – High-pressure switch open
  • Three Flashes – Low-pressure switch open
  • Four Flashes – Auxiliary limit switch open
  • Five Flashes – Outdoor temperature sensor fault
  • Six Flashes – Reversing valve fault
  • Seven Flashes – Defrost control board fault

Understanding these LED codes is crucial for HVAC technicians to identify and resolve any issues that may arise in the Trane Defrost Control Board.

What are the Codes for a Trane Furnace?

There is no one-size-fits-all answer to this question, as the codes for a Trane furnace will vary depending on the model and year of your furnace. However, you can generally find the code information for your furnace in the owner’s manual or by contacting Trane customer service.

How Do You Test a Trane Defrost Board?

There are a few things that you need to do in order to test a Trane defrost board. The first thing that you will need to do is locate the board. Once you have found the board, you will want to remove it from the unit. Next, you will want to check for any visual damage on the board. If there is any damage, you will want to replace the board. If there is no visual damage, you will then want to connect a multimeter to the board. You will want to set the multimeter to ohms and check for continuity between the two terminals on the board. If there is continuity, then the board is good. However, if there is no continuity, then the board needs to be replaced.

How Do You Test a Trane Defrost Board

What Causes a Hard Lockout on a Heat Pump?

A hard lockout on a heat pump is caused by a number of different things. The most common cause is when the outdoor temperature drops below the minimum set point for the heat pump. This can be caused by a number of different things, including a cold front moving in, or simply the temperature dropping at night. When this happens, the heat pump will shut off completely in order to prevent damage from happening to the unit. Another common cause of a hard lockout is when the indoor temperature sensor fails. This can cause the heat pump to think that the indoor temperature is too low, even when it isn’t, and as a result, it will shut off. Finally, if there is a problem with the outdoor fan, this can also cause a hard lockout. If the fan isn’t able to turn on, then the heat pump won’t be able to circulate air properly and it will shut down in order to prevent overheating.

What Does Hard Lockout Mean on a Trane Heat Pump?

If your Trane heat pump is locked out, it means that the system has been turned off and can’t be restarted until a qualified technician resets it. This usually happens when the system detects a problem that could cause damage or harm, such as an overheating condition.

Once the problem has been resolved, the lockout can be reset and the heat pump will operate normally again.

Trane 4Twr4 Fault Codes

If you’re a Trane 4TWR4 owner, you know that these units are some of the most reliable and durable on the market. But even the best units can develop faults over time. If your 4TWR4 is displaying a fault code, it’s important to know what that code means so you can take steps to fix the problem. There are four main fault codes that your 4TWR4 may display:

• Code 01: This indicates that there is a problem with the unit’s condenser fan. The most likely cause is a dirty or damaged fan blade. You’ll need to clean or replace the blade to fix this problem.

• Code 02: This indicates that there is a problem with the unit’s evaporator fan. The most likely cause is a dirty or damaged fan blade. You’ll need to clean or replace the blade to fix this problem.

• Code 03: This indicates that there is a problem with the unit’s compressor. The most likely cause is a blown fuse or tripped breaker.

Trane LED Codes

If you have a Trane furnace, you may be wondering what the different LED codes mean. Here is a list of the most common codes and their meanings:

Blinking Green Light: This indicates that the furnace is in standby mode and waiting for a call for heat. Solid Green Light: This means that the furnace is operating normally.

Flashing Red Light : This code indicates that there is an error with the furnace. The specific error will be displayed on the control panel. Consult your owner’s manual for troubleshooting steps.

Continuous Red Light: This means that the limit switch has been activated and the furnace needs to be serviced by a qualified technician.

Trane Furnace Error Codes

Trane furnace error codes are an essential diagnostic tool for identifying issues with your heating system. These codes not only help technicians identify problems quickly but also provide homeowners with the necessary information to troubleshoot issues before calling a professional.

Here are the most common Trane furnace error codes and their meanings:

  • 2 flashes: Indicates a problem with the pressure switch.
  • 3 flashes: Indicates an issue with the draft inducer motor.
  • 4 flashes: Indicates an open limit switch.
  • 5 flashes: Indicates a problem with the flame sensor.
  • 6 flashes: Indicates an issue with the rollout switch.
  • 7 flashes: Indicates a problem with the gas valve.
  • 8 flashes: Indicates a problem with Low flame sense signal.
  • 9 flashes: Indicates a problem with Igniter.

By familiarizing yourself with these codes, you’ll be better equipped to handle any furnace issues that arise.

Trane furnace error codes

Besides the above, you may also find the following error codes for Trane Furnace:

  • 126: Internal control fault
  • 131: Ignition failure
  • 132: Flame sensor failure
  • 133: Limit circuit fault
  • 147: Low flame signal
  • 151: Blower motor fault
  • 161: AC power loss
  • 164: Open high-limit device

These error codes can help a technician quickly identify the issue and provide a solution, ensuring that your Trane furnace runs smoothly and efficiently.

Trane Troubleshooting Guide

If your Trane unit isn’t working properly, you may be able to troubleshoot and fix the problem yourself. This Trane Troubleshooting Guide will help you identify common issues and provide solutions. First, check the thermostat to make sure it is set correctly. If the thermostat is set too low, the unit won’t run. If the thermostat is set too high, the unit will run continuously without cooling the home. Next, check for power failures. The circuit breaker may have tripped or a fuse may have blown. Reset the breaker or replace the fuse and see if that fixes the problem. If your unit still isn’t running, there could be an issue with the actual unit itself. First, check to see if there is debris blocking the air intake or exhaust vents. If so, remove the debris and try again. Next, check for freezing coils. Ice can build up on the coils and prevent proper airflow. Turn off your unit and let it thaw for several hours before restarting it again. Finally, if all else fails, call a professional for assistance.

Trane Air Handler Blinking Lights

If you have a Trane air handler in your home, you may have noticed that the lights on the unit are blinking. While this may be alarming at first, it’s actually a normal part of the unit’s operation. The blinking lights indicate that the air handler is in standby mode and is waiting for a command from the thermostat. Once the thermostat tells the air handler to start, the lights will stop blinking and the unit will begin heating or cooling your home as needed.

Trane Voyager Error Codes

If you’re getting error codes on your Trane Voyager, it means there’s a problem with the unit. Here are some common error codes and what they mean:

E01 – This indicates that the evaporator temperature is too high. Check to make sure that the coils are clean and that the air filter isn’t clogged.

E02 – This code means that the condenser temperature is too high. Again, check the coils and air filter. Make sure the unit has proper ventilation.

E03 – The third code stands for “freeze protection.” This means that the unit is sensing a potential for freezing temperatures and is shutting down to prevent damage. Check your thermostat settings and make sure the unit is in heating mode. If it still doesn’t work, call a technician. These are just a few of the most common Trane Voyager error codes . If you’re experiencing problems with your unit, don’t hesitate to call a technician or reference your owner’s manual for more information.

Trane Ac Blinking Green Light

If you have a Trane air conditioner , you may have noticed that the green light is blinking. This is normal and indicates that the unit is in standby mode. The green light will blink when the unit is first turned on, and then it will remain lit when the unit is running. If the green light starts blinking again, it means that the unit has been turned off and is in standby mode once again.

Trane Eev Control Board Troubleshooting

If you have a Trane EEV control board that is giving you trouble, there are some things you can do to troubleshoot the problem. First, check all of the connections to make sure they are tight and secure. Next, check the circuit breaker to see if it has tripped. If neither of these solutions solves the problem, you may need to replace the control board.

Heat Pump Defrost Board: Diagnostic Procedures

The Trane Defrost Control Board is responsible for managing the defrost cycle of your Trane AC unit. If there is a problem with the board, it will display an error code on the LED display.

This article lists the codes and what they mean, so you can troubleshoot the issue and get your AC unit up and running again.

Aris

Author: Aris

My name is Aris, and I am a certified HVAC technician. I have been working in this field for over 5 years and have a lot of experience with different AC units. I write here to help people solve their Air Conditioning problems and find the best solutions for their needs. If you are having any issues with your air conditioner or are thinking about buying a new one, be sure to check out my blog!

Related Articles:

  • Mitsubishi Msz-Fh12Na Troubleshooting | Solve Common Issues
  • Carrier APU AC Not Working: Identify and Fix the Issue!
  • P6 Error Code on Your Air Conditioner
  • Trane Ac Unit Fan Not Spinning

My name is Aris, and I am a certified HVAC technician. I have been working in this field for over 5 years and have a lot of experience with different AC units. I write here to help people solve their Air Conditioning problems and find the best solutions for their needs.

If you are having any issues with your air conditioner or are thinking about buying a new one, be sure to check out my blog!

Change Location

Find awesome listings near you.

  • Knowledgebase
  • Ask a Question
  • Pinned     -->
  • Mark Forums Read
  • Who's Online
  • Thanks / Like Statistics
  • Hottest Threads / Posts
  • Contracting Business
  • Advanced Search

Home

  • The ARPA Zone/Open Membership Discussion Forums
  • Tech to Tech Chat - Commercial

Trane voyager spark no ignition

  • Cookie Consent We use cookies to improve your website experience. To learn about our use of cookies and how you can manage your cookie settings, please see our Cookie Policy . By continuing to use the website, you consent to our use of cookies.
  • Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions. All this and much more is available to you absolutely free when you register ; for an account, so join our community today today! We suggest not registering using an AT&T, BellSouth, AOL or Yahoo email address. If you have any problems with the registration process or your account login, please contact support .

Thread: Trane voyager spark no ignition

Thread tools.

  • Show Printable Version
  • View Profile
  • View Forum Posts
  • View Forum Threads

Wiseguy91 is offline

Hey folks, I'm new to the forum. Told a buddy i had a problem and he said to come here. I'm working on a Lp Trane GRAA 350000 btu rooftop. Got a call after the propane tank was refilled because the unit failed to light. Purged the gas train and still got nothing. Checked for spark and had a bright one. The gas valve manometer port was striped so I changed it out (Honeywell single stage standard opening). Changed pilot assembly while I was at it just in case. Gas pressure was 10.8 in. Only thing I can think of is bad mix but I've tried a range of pressures. Does anyone have any ideas?

jmsmars1's Avatar

checked for 24v to valve? was the 10.8 in WC the inlet or outlet?

alcomech is offline

Are you sure that is a spark ignition and not a hot surface ignition. What is the Model No. and Serial no. Is that a two stage gas valve. Did you say that you replaced the gas valve and if so was that an O.E.M. parts replacement. You have to be careful because sometimes those valves are rated for negative manifold pressure. Are the controls Microtech

jayguy's Avatar

he mentioned that the unit is a GRAA which is a make up air unit originally designed by Sterling. it is a spark pilot ignition. as mentioned before, you measured the gas pressure where? the inlet gas pressure is important, but with no fire, the outlet is important too...got gas coming out of the pilot?
"Right" is not the same as "Wise". Don't step on my favorite part of the Constitution just to point out your favorite part. Just because you can measure it, doesn't mean it is important. Just because you can't measure it, doesn't mean it isn't important.
Thanks for the responses. I have 24v to gas valve and pressure was measured going in. Adjusted pressure but haven't measured the pressures out yet. Pilot valve has gas coming out but won't light from the spark. I replaced the valve that with the same single stage Honeywell that was on it. On my way to the job site now so ill keep you posted.
Pilot assembly*
Also the pilot assembly was not a LP so I changed the orafice. I assumed they where all the same but this could very well be the problem.

hands's Avatar

Is this a Direct or Indirect fired MAU?
Indirect. But I managed to figure it out. The pilot assembly was not putting out the proper amount of gas becouse I used the wrong nozzle when I converted it to propane. Whould have been nice to just get the right assembly the first time but it was 2 weeks out. Switched out the nozzle abd cleaned out a ton of soot from the burners and she fired up. Original pilot assembly was clogged up bad too. Thought it was wierd for a 4 year old unit but it sits unused most of the time.

valdelocc's Avatar

Great! glad you didnt have to call a HVAC contractor, they are expensive you know.
Contractor=My boss I'm in training in a family business.

Betabass's Avatar

Good job........ Beta
  • Private Messages
  • Subscriptions
  • Search Forums
  • Forums Home
  • The #1 question asked by NEW MEMBERS. Please read this...
  • Questions About Becoming A Professional Member? Step Inside...
  • SITE Software Issues? Post Them Here
  • RULES for AOP - Owner Assistance and Contractors
  • AOP Residential HVAC and Refrigeration (Beenthere Zone)
  • AOP Commercial HVAC and Refrigeration
  • General Discussion
  • Job Wanted/Needed Discussion
  • Industry and Forum News
  • Webinars and Virtual Events
  • Tech to Tech Chat - Residential
  • Refrigeration & Ice Making
  • Members Inventions **NEW
  • Test & Balancing Forum NEW
  • Control Sales Forum
  • Professional Controls Forum
  • Control Jobs Forum
  • Chillers Open Forum
  • Energy Efficiency and Building Performance Discussion NEW
  • Commercial Food Service Equipment
  • Residential Geo Thermal / Water Source
  • Commercial Geo Thermal / Water Source
  • Indoor Air Quality
  • Tools & Test Equipment
  • Food and Grill Forum
  • "Wall of Pride" - Pictures
  • "Wall of Shame" - Pictures
  • How To Become a Pro and Rules For Pro Members
  • Pro's Forum: General Discussion
  • Charlie's Corner (Icemeister)
  • HVAC Basics **NEW
  • Pro Forum: Refrigerants and EPA regulations **NEW
  • Pro's Forum: Business & Marketing
  • Pro Forum: Residential Refrigeration and Appliances **NEW
  • Pro's Forum: Sales
  • Pro Forum: Equipment Recalls and Bulletins **NEW
  • Pro's Forum: Residential
  • Pro's Forum: Commercial
  • Pro's Forum: Geo Thermal / Water Source
  • Pro's Forum: Refrigeration & Ice
  • Pro's Forum: Chillers
  • Pro's Forum: Oil Burners
  • Pro's Forum: Hydronics/Boilers
  • Pro's Forum: Building Science Discussions
  • Pro's Forum: Training and Education
  • Pro's Forum: Instructors Forum NEW
  • Pro's Forum: Tips 'n Tricks of the Trade
  • Pro's Forum:The Gun Enthusiast
  • Frequently Asked Questions About Submissions
  • Manufacturers' Technical Information
  • Articles Authored by Others
  • Self-Authored Articles
  • Submit Quiz Questions
  • About the Suggestion Box
  • Voice Your Opinions
  • Share Ideas
  • Report Problems
  • Educational, Training & Reference Information
  • Manufacturer's Technical Information Links
  • Quiz Questions
  • Open Forum Discussion
  • Split Systems, Package Units, Furnaces
  • Geothermal / Water Source Heat Pumps
  • Specialty Systems
  • Boilers – Hydronic, Steam
  • Accessories – Humidifiers, Air Cleaners, HRUs, Fans, Filters, etc
  • Components – Coils, Heaters, Motors, etc.
  • Compressors
  • Oil Burners
  • Systems - General
  • Accessories – Pumps, Cooling Towers, Evap Condensers, etc
  • Components – Valves, Motors, Condensers, Evaporators, etc
  • Refrigeration Systems
  • Evaporators, Condensers, Etc.
  • Valves, Regulators, Filters, Etc.
  • Walk-Ins, Cold Storage
  • Food Service Equipment, Display Cases
  • Supermarket Cases & Compressor Systems
  • Ice Machines
  • Controls, Motors, Etc
  • HVAC Load Calc Software
  • Refrigeration Load Calc Software
  • HVACR Software & Online Training
  • HVACR Calculators & Apps
  • Formulas and Calculations
  • In Memoriam
  • Licensing, Laws, Codes and Certification
  • Jokes, Quotations, Humor, Wisdom Pills
  • Practice, Testing Area
  • Plumbing Forum Rules
  • Plumbing General Open Forum
  • Pro's Forum: Plumbing Discussion
  • Electrical Forum Rules
  • Open Discussion Electrical
  • Photovoltaic
  • New Products
  • Bonding & Grounding
  • Motors & Motor Controls
  • Test & Measurement
  • Tools & Equipment
  • Code Violations
  • Pro's Forum: Power Quality
  • Pro's Forum: Calculations & Electrical Theory
  • Pro's Forum: Electrical Business & Marketing
  • Pro's Forum: Estimating
  • Job Postings

vBulletin Message

The following errors occurred with your submission, quick reply, register now.

Please enter the name by which you would like to log-in and be known on this site.

  • Confirm Password:

Please enter a password for your user account. Note that passwords are case-sensitive.

  • Email Address:

Please enter a valid email address for yourself.

  • HVAC/R Contractor
  • HVAC/R Technician/Installer
  • HVAC/R Wholesaler/Distributor
  • HVAC/R Manufacturer
  • Manufacturer Rep
  • HVAC/R Consultant
  • HVAC/R Engineer
  • Facilities manager/Mechanical Engineer
  • Homeowner or Building/Equipment Owner (We welcome homeowners and Building owners. Help us customize your experience) Please post in the AOP Section
  • Residential HVAC
  • Light Commercial HVAC (up to 25 tons)
  • Commercial HVAC (over 25 tons)
  • Refrigeration
  • Hydronic Heating
  • Building Automation/Controls

Posting Permissions

  • You may post new threads
  • You may post replies
  • You may not post attachments
  • You may not edit your posts
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

  • HVAC-Talk.com

© VerticalScope Inc. All Rights Reserved.

IMAGES

  1. Ignition board replacement on a trane voyager roof top unit

    trane voyager ignition board flash codes

  2. Voyager 2 Modulating Heat Board (CFMB) LED Flash Codes (Old Fasco vs

    trane voyager ignition board flash codes

  3. Voyager 2 Modulating Heat Board (CFMB) LED Flash Codes (Old Fasco vs

    trane voyager ignition board flash codes

  4. Trane Voyager Troubleshooting Manual

    trane voyager ignition board flash codes

  5. Ignition Controller Board Module Diagnostics

    trane voyager ignition board flash codes

  6. Trane Voyager 12 5 To 25 Tons Installation And Maintenance Manual

    trane voyager ignition board flash codes

VIDEO

  1. Voyager 3_1_10.wmv

  2. Trane Voyager igniter replacement

  3. Trane XE80 Ignition Failure FIXED! #tips #diy #hvac #heater #shorts #checkthisout #fixed

  4. Trane VRF Error code P6 (English)

  5. Honeywell Voyager® 1200g Competitive Scribble Test video ( C)

  6. Trane Voyager with a few issues

COMMENTS

  1. List of Light Commercial LED Codes

    List of Light Commercial LED Codes. LED Blink Codes. Electromechanical Ignition Board. 2 flash - 1 Hour Lockout. 3 flash - Pressure Switch. 4 flash - TCO Open. 5 flash - Flame W/O Gas. 6 flash - Rollout Switch Open. 7 flash - W1 / W2 Swapped.

  2. What are the gas heat fault codes for Reliatel controlled ...

    Wiring issue or problem with ignition module or RTRM. 2 Flash. System lockout - failure to sense flame. Failure to ignite, no spark, low/no gas pressure. 4 Flash. TCO (high temperature limit) circuit open. excessive heat in the combustion chamber, low airflow, 5 Flash. Flame being sensed, but gas valve not energized.

  3. PDF User guide

    Terminal Board and the unit will walk through its operational steps. ... (Voyager III) Voyager III Con˜guration J12 ... STEADY FLASH STEADY ON OFF LED FLASH CODES 24 VAC 24 VAC XFMR1 MBUS 2-10 VDC DAMPER OVERRIDE 2-10 VDC DAMPER POSITION 2000 1500 UL 1000 500 1900 LL 300 Pre-RTRM V. 8 DCV SETPOINT

  4. PDF Installation, Operation, and Maintenance Voyager™ 3

    RT-SVX089B-EN 7 Model Number Description 60 Hz Description Digit 1, 2 — Unit Function TC = DX Cooling, No Heat TE = DX Cooling, Electric Heat YC = DX Cooling, Natural Gas Heat

  5. PDF Trane voyager fault codes

    Physical Books trane voyager fault codes Benefits of a Digital Library Creating a Diverse Reading Clilection trane voyager fault codes 13. Accessing trane voyager fault codes Free and Paid eBooks trane voyager fault codes Public Domain eBooks trane voyager fault codes eBook Subscription Services trane voyager fault codes Budget-Friendly Options 14.

  6. Trane Voyager Troubleshooting Help

    Reliatel control boards have "Trane" terminals 1-12 or so as well as "conventional" terminals R-G-Y-W etc directly on the board. Older Voyager units have Voyager or "black book" controls which require a "CTI" or Conventioal Thermostat Interface board to use a regular 24v stat. Post a pic of what you're working on, it would help greatly.

  7. PDF Voyager™ II Rooftop Units

    into a sealed drum where ignition takes place. It is more reliable to operate and maintain than a multiple burner system. † The hot surface ignitor is a gas ignition device which doubles as a safety device utilizing a continuous test to prove the fl ame. Weather Tight Top and C abinet † Voyager units incorporate the Trane-Tite-Top (T 3). Each

  8. Ignition Controller Board Module Diagnostics

    Slow Flash Rate Normal, call for heat (¾ second on, ¼ second off) 1 Flash : Loss of Communication 2 Flashes: System Lockout: Failed to detect or sustain a flame. (failure to ignite, no spark, low/ no gas pressure, etc.) 3 Flashes: Pressure switch problem detected. (no vent air flow, bad CBM, closed at an initial call for heat). Auto reset.

  9. Trane Defrost Control Board LED Codes

    The codes and their meanings are as follows: Steady Green LED - The system is operating normally. Steady Red LED - The defrost control board has detected a fault and is in lockout mode. Flashing Red LED - The sensor is not detecting proper temperature, indicating a possible faulty sensor or a wiring issue. Flashing Green LED - The ...

  10. YSC

    YSC - Ignition Fault Codes. Article ID: 494. Last updated: 13 Nov, 2020. Trane Package Unit: YSC. Re: Ignition Lockout Codes. Trane YSC package units are multi-stage gas/electric units. These units utilize an Ignition Control Board (ICB) with a built-in spark generator for electronic ignition control. The ICB has a diagnostic light to indicate ...

  11. List of Light Commercial LED Codes

    List of Light Commercial LED Codes. LED Blink Codes. Electromechanical Ignition Board. 2 flash - 1 Hour Lockout. 3 flash - Pressure Switch. 4 flash - TCO Open. 5 flash - Flame W/O Gas. 6 flash - Rollout Switch Open. 7 flash - W1 / W2 Swapped (W2 calling before W1)

  12. Voyager 2 Modulating Heat Board (CFMB) LED Flash Codes (Old ...

    Range should be +/- 10%. Measure the voltage at the board and at the combustion fan motor. Overvoltage limit of the board is approx. 270V. 4 flashes - Over Temperature - This board is not connected to any temp/safety switches in the unit, this fault should not be experienced. 5 flashes - Over Current. New ICM Board. LED Codes (ICM)

  13. What are the gas heat fault codes for Reliatel controlled ...

    Wiring issue or problem with ignition module or RTRM. 2 Flash. System lockout - failure to sense flame. Failure to ignite, no spark, low/no gas pressure. 4 Flash. TCO (high temperature limit) circuit open. excessive heat in the combustion chamber, low airflow, 5 Flash. Flame being sensed, but gas valve not energized.

  14. Trane Voyager No Heat : r/HVAC

    Looking for advice, Working on a 5 ton Trane Voyager YCD. Not getting 24v to the gas valve. Unit goes through the order of operations normally. Limits closed, boards replaced, board getting 24v on "24v" and "TH+" correctly. Unit makes one attempt for ignition and does not recycle or return any flash codes.

  15. How do I retrieve fail codes from the RTRM when I have a 2 ...

    1. Take the following 4 DC voltage measurements on the J6 connector of the RTRM. Table 1. Fail Codes. Supply air temperature sensor failure and unit is CV with modulating heat or modulating reheat. High or low pressure switch has opened more than 3 times. Supply air temperature is invalid and unit is VAV or CV with modulating reheat.

  16. 80 Volts Hot Surface igniter Trane Voyager

    Trane Voyager 2 No Heat Installed New Ignition board and carefully installed correct,new hot surface igniter Combustion Motor good , both speeds, can smell gas, valve OK No Flame, checked wires,OK 82 Volts AC to H.S.I. Jack Tech ordered new 208 volt by 120 Volt transformer . Flame check pins 1Volt= 1uA.

  17. Service Manual/ Error Codes and Diagnostics /Wiring Diagrams

    Learn how to service, diagnose and wire Trane branded Samsung units with this comprehensive manual. Download or access online.

  18. Trane voyager spark no ignition

    Trane voyager spark no ignition. Hey folks, I'm new to the forum. Told a buddy i had a problem and he said to come here. I'm working on a Lp Trane GRAA 350000 btu rooftop. Got a call after the propane tank was refilled because the unit failed to light. Purged the gas train and still got nothing.