Galvin Power

Galvin Power is reader-supported. When you buy via our links, we may earn a commission at no cost to you. Learn more

What is a Shunt Trip Breaker and How Does It Work?

Written by  Edwin Jones  / Fact checked by  Andrew Wright

what is a shunt trip breaker

What is a shunt trip breaker? Does it add protection to your electrical system?

The shunt trip breaker is a combination of the shunt trip accessory and the main circuit breaker. This installs on the main breaker to add protection to your electrical system. This adds security to your electrical system as it manually or automatically cuts the electric supply in your circuit.

This accessory can help prevent short circuits and avoid electrical damage should a disaster occur in your home.

Let me tell you more about the shunt trip breaker to help you decide if you need additional protection for your electrical system.

Table of Contents

What is Shunt Trip Breaker and How Does It Work

Where are shunt trip breakers most used, how to install a shunt trip accessory to the breaker.

shunt-trip-relay

You should know that shunt trip breakers are different from GFCI circuit breakers.

The GFCI circuit breaker contains one big white tail wire for neutral connections only. It cannot be connected to any control package because the GFCI circuit breaker is solely designed to detect a sudden electrical surge. It has no other purpose but to cut power in case of a short.

Meanwhile, the shunt trip breaker wiring comprises two wires. One connected to the ground, and another to a control system. The control system can be connected to a sensor or to a manual switch. When activated, the shunt trip accessory will cause the main breaker to trip.

For example, if you install a shunt trip with a smoke detector, it will activate and cut off the power should the smoke sensor trigger. It can also be installed with a remote switch , allowing you to trip your breaker manually.

It is crucial to know the difference between a regular circuit breaker and a circuit breaker installed with shunt trip accessories.

shunt-trip-definition

The shunt trip definition means that it is a way to cut off electrical power through other sensors, not just via thermal activation. Since this is an optional accessory for a circuit breaker, it is not required for a home electrical system.

However, it is recommended for added safety. This is especially true if you’re working with industrial machinery. Furthermore, you can use it as a manual emergency switch to shut down your main breaker.

Before installing a shunt trip, consider its cost and your existing system. You may need to change the breaker panel  and circuit breakers, especially if it is not compatible with shunt trips. You may also need a new line to connect the remote emergency switch to your breaker box.

Generally, most commercial kitchens, elevators, and offices have this shunt trip breaker because it is required. Commercial kitchens use this device in compliance with ANSI/ASME CSD-1, while elevators and escalators comply with ASME A17.1. These codes refer to the controls and safety standards provided by ASME’s.

This question is a topic of discussion among Reddit members as well. Join the conversation here:

Found at a dominos by u/Guilty_Sympathy_496 in electricians

Mostly, installing a shunt trip relay requires that the breaker and the shunt be from the same maker. Also, not all breaker models are compatible with this accessory.

Once you’re sure that your system can take a shunt trip accessory, installation is pretty much straightforward. You can watch this video by Aaron CBIONE for some tutorials.

Note: Every circuit breaker comes with different instructions. It would depend on the brand and model of the breaker .

However, the critical part of every installation is that you need to connect the shunt to your sensor. You may need a shunt trip breaker diagram as a reference to ensure correct installation.

Also, check the brand and model of your breaker before proceeding with the installation. Some makers only allow a factory install of the shunt trip and other accessories. DIY installation may void the warranty of your breakers. It’s best to read up on the manual or consult an electrical professional before making any changes.

What is a shunt trip breaker? The shunt trip is an optional accessory for a circuit breaker for added protection to your system. It is designed to connect to a secondary sensor. It will trip the breaker automatically if the sensor is triggered. It can also be activated via a remote switch that you can install.

Do you think that a circuit breaker is enough to protect your investment? Or do you want an additional layer of protection for your electrical circuit? If you’re not decided yet, reach out to me in the comments section below, and I will be happy to help you.

Andrew-Wright

I am Andrew Wright. With 8 years of experience designing, installing, and maintaining electrical power systems. I love my job, and I have always wanted to offer others the necessary help so they can take care of their houses.

  • Semiconductors
  • $2 for 1-8 layer PCBs

What Is A Shunt Trip Breaker & How Does It Work? Detailed Guide

Hello readers welcome to the new post. In this post, we will learn What Is A Shunt Trip Breaker & How Does It Work. The shunt trip breaker is a combination of a shunt trip accessory and a main circuit breaker. it connects to the main breaker for the protection of the electrical system. it also added security to the system since it manually or automatically cut the supply in the circuit. In this post, we will discuss the all details shunt trip breaker and other parameters. So let’s get started What is a shunt trip

Table of Contents

What is a Shunt Trip Breaker?

If the circuit breaker trips it finds faults condition and automatically shuts off the current flow to prevent the circuit from overheating.  The shunt trip breaker is an optional device for a circuit breaker that helps to trip the breaker remotely in any instant or automatically in case of surge saving any damage and instrument damage.

There are 2 main types of shunt trip breakers first one is manual and the second one is automatic.

Manual witches help to off the breaker externally with the use of the remote button. Automatic switch off power when detecting surges from the external power supply.

What Is A Shunt Trip Breaker

 How Does a Shunt Trip Breaker Work?

Normally the current passes through the circuit breaker. But if these currents become high surges, the larger surge of power changes the electromagnet below the breaker switch, tripping the cutting power and switch.

The shunt trip breaker offers extra techniques to charge the electromagnet and trip switch, helping remote or automatic power shutoff. Some hunt trips are connected to an external power supply.  When power surges get that source, signal flow from shunt trip to the breaker, mechanical cutting power.

The shunt trip can make a connection with the remote switch outside the building. Pushing the button on the switch sends a surge through shunt trip wiring and off the power.

 Components of  Shunt Trip Breaker

Read more  Top Reasons Why Electric Outlet Stopped Working Breaker Not Tripped?

A shunt trip breaker comes with differnt components:

  • The frame of the shunt trip circuit breaker works as an external protective housing and covers all inner components. it is made with the use of durable materials like metallic that help to avoid damage to sensitive inner circuits.
  • Contacts are the main part of the circuit breaker that carries electric current. in a shunt trip circuit breaker, there are two types of contacts, main contacts, and auxiliary contacts. The main contact is used for normal power transmission, and auxiliary contacts are used for connecting the external control system

Operating Mechanism:

  • The working phenomena in shunt trip circuit breakers help to open and close contacts. it comes with latch releases and trip units. The latch releases are used for maintaining contacts in the closed position until the trip mechanism works. The trip unit detects abnormal electrical conditions and starts the tripping process.

Electromagnet:

  • At the core of the shunt trip circuit breaker electromagnet exists, which is important for working. If the external signal gets, the electromagnet activates and produces a magnetic field. This field work on latch releases resulted to open circuit breaker contacts.
  • It is the main part of the shunt trip breaker that operates uniformly with an electromagnet. its working is to get an external signal and convert into electrical energy. this energy is used to producing the field needed for tripping breaker.

Why Are Shunt Trip Breakers Important?

irrespective optional nature of the shunt trip breaker, it can be an important safety instrument in a power system. As a result, many engineers use this breaker as a layer of security since they save damage during power surges.

This breaker is good for many fonts but it’s commonly used during fire. By turning off power if a fire breaks out, the electrical hazard is no main risk. Some connections shunt trip to smoke alarm in homes, for power automatically off when detector trigger alarm. It not be good option, since in some conditions smoke alarm gets off due to steam from the shower of smoke from the kitchen

 Applications of Shunt Trip Breakers

  • In commercial buildings like offices, and shopping malls, shunt trip circuit breakers are connected to ensure sure safety of many components and protect them from electrical faults. It also connected with a building management system to help remote operations
  • Industrial facilities mostly work with high-power machines, so electrical safety is needed. Shunt trip breakers are used in such facilities for protection from faults and to reduce the chances of electrical accidents.
  • Laboratories and research facilities also use these breakers since they are equipped with sensitive devices.
  • There is a need for a regular power supply for critical patient care. Shunt trip breakers help to make sure emergency power is constant without any interruption.
  • Data centers come with computing devices and sensitive data. Shunt trip breakers are used to protect these facilities from electrical hazards.

 Advantages of Shunt Trip Breakers

  • The main benefit of a shunt breaker is that it can remotely shut off in case of any fault. It quickly works and disconnects power in fire which helps to avoid damage in the home and protects people.
  • These devices also increase safety levels and security by automating off power to the circuit if there is any fault. it helps to save electrical fires and any other damage.
  • The shunt breaker is easily connected and confined with a power system, so it is easy to install the device in the building.
  • The shunt breaker is a less cost solution for safety measures in buildings and industries. it is less costly to buy and connect and helps to save homes and buildings in the result of high fault.
  • Shunt breakers support many electrical systems and devices so it is versatile devices that are used for the protection of circuits.

 Comparison with Other Circuit Protection Devices

Shunt trip breakers vs. standard circuit breakers.

The basic difference between shunt trip breakers and regular circuit breakers is their function. Regular breakers are manually operated and based on a user-to-flip switch if requried or on current overloading that triggers the unlatching process.

While shunt trip breaker provdies more layers of controls. it can be triggered remotely with the use of a switch or automated system. These features allow them to immediately off power in case of fault.

Shunt trip breakers vs. ground fault circuit interrupters (GFCIs)

GFCI monitors equality between L1 and L2, if there is more than predefined difference in trips. The shunt breaker is a combination type device that combines in regular breaker with its regular function trip it has a remote control to trip breaker.

Ground fault breakers monitor current on neutral wire flowing back to the neutral bar, the four to six-milliampere different trip breakers, and shunt trip breakers can tripled remotely from other switches or points. In industrial uses, it is used to shut off in emergency condtion, when access to an electrical panel is difficult.

Shunt trip breakers vs. arc fault circuit interrupters (AFCIs)

Shunt Trip Breaker

  • It used for overloading and short protection
  • its working principle is based on thermal magnetic trip
  • Its detection range is 10 to 1000A
  • its response time is 10 to 20 milliseconds
  • It used for arc fault protections
  • It works based on a microprocessor for detecting arcing
  • The detection range is 5 to 6000 A
  • Response time is 10 to 40 milliseconds

What Are 3 Types Of Shunt Trip Breakers?

  • Standard breakers
  • Arc fault circuit interrupter circuit breakers

Shunt trip breaker wiring

Follow these steps for shunt trip breaker wiring.

  • First of all, see the diagram shown below.
  • Arrange requried tools and materials like wire strippers, nuts, and voltage tester.
  • Remove the power and wire that shunt the breaker according to instructions.
  • Again connect power to the circuit and test breaker to check that working well

Diagram of Shunt Trip Breaker Wiring Diagram

Diagram of Shunt Trip Breaker Wiring Diagram

WHICH TYPE OF SHUNT TRIP BREAKER TO USE?

The manual breaker is best to use for small buildings or conditions where any technical staff is available to reset the breaker,. The automatic breaker can be best for larger-size buildings or conditions where there is no option for staff for breaker resetting.

it is also preferred for trigger shunt trip breakers at a distance or remotely. These relays are connected to fire alarm systems and can send a signal to the breaker for tripping if there is any fault.

Read more  How Many Outlets on a 15 Amp Circuit Breaker?

How Many Outlets on a 15 Amp Circuit Breaker?

60 Amp Wire Size – Which AWG is Best for 60 Amp Breaker

Difference Between a Single and Double Pole Breaker

Where is the Doorbell Breaker Located? Easy Way to Findout

Difference Between Fuse and Circuit Breaker

How does a shunt trip breaker work?

The shunt trip is a device in the circuit breaker that mechanically trips the breaker when power is given to shunt trip terminals. Power for shunt trip does not come in breakers, so it provided from an external source

How is a shunt trip breaker wiring?

Make the connection of accurate voltage (120V to 240V for the -1021 suffix) with 2 terminals on the shunt trip. Land with a leg from source contact on one terminal and a neutral wire. (L2 , X2 ) to the other terminal

What is the purpose of a shunt with a relay?

Shunt relays are used to bypass normal controls like switches , dimmers, or panel-mounted relays when employed on an emergency circuit.

What is shunt trip and under voltage?

The shunt trip coil is connected to the breaker to offer a remote trip of the breaker but Undervoltage or no voltae coil is connected to offer automatic tripping when power losses occur or when there is a major voltage dip.

Where is shunt trip used?

The shunt trip helps to remotely and fastly turn off the breaker when needed especially in conditions where safety and speed is important, like during a fire or when there is needed to isolate certain areas of the electrical system without physically going to the breaker

What is the difference between shunt and resistance?

The shunt is an electrical device that produces a low resistance path for current. It helps current to flow to another point in cirucit. Shunts are also referred to as ammeter shunts or current shunt resistors.

What is the purpose of a shunt breaker?

its main purpose is to remotely and fastly turn off  circuit breaker when necessary

Is the shunt resistor AC or DC?

Shunt provdies DC mV signal for driving moving coil ammeter, overlading protection, and control units for high amper range.

Where are shunt trip breakers required?

These breakers are used in commercial  and industrial buildings, also for facilities where safety is a top priority

Why is it called a shunt resistor?

In older circuits, resistors connected in parallel to the ammeter as shunts for expanding the current measuring range called shunt resistors. but now resist used for detection circuit current  collectively referred to as shunt resistors

Why is low resistance called shunt?

When a resistor is connected with another resistor of low value, then the equivalent resistance is less the lowest resistor, that is shunt resistors.

What is another name for a shunt resistor?

Shunts also called ammeter shunts  or current shunt resistors.

What is a unit of shunt resistance?

The unit of shunt resistance is ohm (Ω).

What is shunt resistance formula?

The shunt resistance formula is:

  • Rs is the shunt resistance
  • V is the voltage of the shunt resistor
  • I is the current passing through the shunt resistor

What is shunt release in a circuit breaker?

The shunt releases is opening coil plus release. Thermal trips and electromagnetic trips also use trip units. use a certain voltage to shunt trip the coil, and the breaker will trip and open.

What is the difference between a shunt trip and series trip?

What are the different types of shunt trip breakers, does a shunt trip breaker need a neutral, what is the difference between shunt trip and a shunt close.

When used as a shunt trip the coils trip breaker when a rated voltage is given. When used as shunt close, coils closes breaker when voltae is provided

Share this:

Wholesale PCBs SMT Stencil & PCBA Service Provider

Special offer:$2 for 1-8 layer PCBs 

Sign Up & Get 54$ Coupon

Author:  Scott Spencer

I am professional content writer have professional degree in engineering. I have worked in different famous companies and also providing technical and seo based services clients all over the world. With that i am sharing my knowledge to engineering and technical students and new learners to enhance their learning and get new ideas in technical fields. Follow him on Twitter and Facebook .

Related Posts

Can 3D printers create complex structures? June 6, 2024

What are Alkaline Batteries? A Buying Guide  June 4, 2024

What is a Waterjet Cutting Machine and How Does it Work May 29, 2024

How to Get Bugs Off Car

Why Should Industries Choose Oil-Free Air Compressors? May 14, 2024

The 6 Critical Issues in the Construction Industry and Suggested Solutions in 2024 May 13, 2024

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Save my name, email, and website in this browser for the next time I comment.

Post comment

low voltage shunt trip breaker

  • Electrical Repair
  • Lighting Installation
  • Hot Tub Wiring
  • Emergency Electrical Service
  • Ceiling Fan Installation
  • Generator Installation
  • Commercial Lighting Services
  • Electrical Inspection
  • What Is a Shunt Trip Breaker and How Does It Work

What Is a Shunt Trip Breaker and How Does It Work?

First things first: what is a shunt trip breaker? A shunt trip breaker is a specialized circuit breaker that is designed to remotely shut off power to a circuit in emergency situations, such as a fire or security breach. These breakers are commonly used in commercial and industrial buildings, as well as other facilities where safety is a top priority. In this article, we'll explore this type of breaker in detail and explain why hiring an  electrical services provider for a wiring shunt trip breaker is essential. 

The Many Benefits of a Shunt Breaker

Let’s recap: a shunt trip breaker is an electrical component connected to a circuit breaker and allows for remote operation through a schematic and AMP connection. Now that you know what a shunt trip circuit breaker is, it's time to move to the next part of this article: the benefits of using a shunt breaker.

  • Remote Shut-Off: One of the main benefits of shunt breakers is that they can be remotely shut off in the event of an emergency. This allows them to quickly and easily disconnect power in a fire or other emergency, which can help prevent damage to the building and protect the occupants.
  • Increased Safety: Besides remote shut-off, shunt trip circuit breakers provide an added level of safety and security by automatically shutting off power to a circuit in the event of an emergency. This helps prevent electrical fires and other hazards, protecting both people and property.
  • Easy Installation: Shunt breakers are relatively easy to install and can be integrated into existing electrical systems, making it possible to retrofit older buildings with these devices.
  • Cost-Effective: A shunt breaker is a cost-effective solution for increasing safety and security in commercial and industrial buildings. They are relatively inexpensive to purchase and install and can help prevent costly damage to the building and its contents in case of any emergency.
  • Compatibility: Shunt breakers are compatible with a wide range of electrical systems and devices, making them a versatile and practical solution for increasing safety in various settings.

How Does a Shunt Trip Breaker Work?

A shunt trip breaker works by tripping the breaker when it receives a signal from an external device, such as a fire alarm or security system. This helps to prevent dangerous electrical fires or other hazards. When an emergency occurs, the external device sends a signal to the breaker, which causes the breaker to trip and open the circuit, interrupting the flow of electricity and preventing power from reaching the circuit, allowing for a quick and easy power disconnection.

Types of Shunt Trip Breakers

Now that you know the answer to "How does a shunt trip breaker work", it's time to discover about the two main types of shunt trip breakers.

  • Manual Shunt Trip Breaker: This type of trip breaker requires manual intervention to reset the breaker after it has been tripped, meaning someone must physically go to the breaker and reset it after an emergency situation. This breaker is typically used in smaller residential buildings or situations where a dedicated staff member is available to reset the breaker.
  • Automatic Shunt Trip Breaker: This type of breaker can automatically reset itself after being tripped and is typically used in larger buildings or in situations where there is not always someone available to reset the breaker. These breakers are often connected to fire alarm systems or other emergency management systems for auto-reset.

When is a Shunt Trip Breaker Required?

If you're wondering when is a shunt trip breaker required, know that it is required in any electrical system where there is a need to quickly and easily shut off power in the event of an emergency, such as a fire or security breach. Continue reading as we describe the importance of using shunt trip breakers and how to figure out which one you need to use for your building or facility.

The Importance of Using a Shunt Trip Breaker

  • Shunt trip breakers automatically shut off power in emergencies.
  • They prevent dangerous electrical fires and other hazards.
  • They allow for quick and easy power disconnection in emergencies.
  • They are easy to install and cost-effective solutions for increasing safety.
  • They can be connected to fire alarm and emergency management systems.
  • They ensure that the electrical system is in compliance with safety regulations.
  • They are a versatile and practical solution for increasing safety in various settings.

Which Type of Shunt Trip Breaker to Use?

A manual breaker may be appropriate for a smaller building or in situations with a dedicated staff member available to reset the breaker, while an automatic breaker may be more appropriate for a larger building or in situations where someone is not always available to reset the breaker. Another option to consider is the use of a shunt trip relay, which can be used to trigger a shunt trip breaker remotely. These relays are typically connected to fire alarm systems or other emergency management systems and can send a signal to the breaker to trip it when an emergency occurs.

Shunt Trip Breaker Wiring Diagram

shunt trip definition and scheme for beginners

If you're wondering how to wire a shunt trip breaker, know that wiring can seem like a daunting task, but with the right knowledge and tools, it can be done relatively easily. Follow the steps below:

  • Obtain a "How to wire a shunt trip breaker wiring diagram." (Check above).
  • Gather necessary tools and materials such as wire strippers, nuts, and a voltage tester.
  • Disconnect the power and wire the shunt breaker according to the instructions provided.
  • Reconnect power to the circuit and test the breaker to ensure it works properly.

It is important to pay close attention to the diagram and follow the instructions carefully. This will ensure that the breaker is wired correctly and functions. Once the wiring is complete, you can reconnect the power to the circuit and test the breaker to ensure that it is working properly. It is always better to consult with a professional if you aren't confident about the wiring process. 

What Does a Shunt Trip Breaker Do?

We hope by now you know what does a shunt trip breaker do, but here's a recap: a shunt trip breaker is a specialized circuit breaker that protects your house electrical systems from damage or hazards in emergencies. It works by tripping the breaker when it receives a signal from an external device, such as a fire alarm or security system, preventing dangerous electrical fires or other regular hazards.

Nevertheless, it is important to understand what does shunt mean in electrical terms and the role of electrical shunt trip breakers in commercial and industrial settings. Finally, to determine the appropriate type of breaker for your specific needs, it is best to consult an electrical services provider. If you're based in Colorado or surrounding areas, McCarrick Electric has got you covered.

Superior Electrical Solutions in Colorado 

At McCarrick Electric, we have 25+ years of experience providing top-quality electrical services in Colorado. We value all of our customers, and that's why we offer a 15% discount for first-time residential clients and veterans. We take pride in our integrity, attention to detail, and cost-effectiveness. For more information, connect with us via our contact form or give us a call.

Latest Blog Entries

Find out why your main circuit breaker tripped

What to Do If Your Circuit Breaker Keeps Tripping?

Breaker box on outside image

Why Is Your Breaker Box Outside House? Here Are the Reasons

wondering what to do if GFCI not working after replacement

Why Won’t My GFCI Outlet Reset? How to Troubleshoot a GFCI Outlet

Learn how to prevent a short in wiring

5 Ways to Prevent Short Circuits

GE Shunt Trip Manual

  • Circuit breakers

GE Shunt Trip Manual

  • page of 4 Go / 4

Advertisement

Quick Links

Related manuals for ge shunt trip.

Circuit breakers GE Spectra Series Installation Instructions

Summary of Contents for GE Shunt Trip

  • Page 1 Lockout The catalog numbers for various voltage applications accessories, shown in Figures 1 and 2, can be installed are listed in Table 1 for the Shunt Trip and in Table 2 in 800-4000 ampere frame Power Break® II circuit for the Shunt Trip with Lockout.
  • Page 2 Bell Alarm-Alarm Only or Bell A l a r m with Lockout accessories when a shunt trip occurs, The Shunt Trip accessory is installed in the accessory with the procedure described in the Accessory compartment through the front of the circuit breaker Configuration section.
  • Page 3 Apply at least 55% of the rated ac voltage at least Lockout also change state. (The factory switch 75% of the rated de voltage to the Shunt Trip; the setting is disabled.) breaker should trip immediately. When an Undervoltage Release accessory causes...
  • Page 4 Check that the accessory is Shunt Trip. completely inserted; reinsert if necessary. If a 1 2 Vdc Shunt Trip is installed, check that the polarity of the control power matches that shown on the label of the Shunt Trip accessory.

This manual is also suitable for:

Rename the bookmark, delete bookmark, delete from my manuals, upload manual.

Shunt trips

low voltage shunt trip breaker

Are you looking for support or purchase information?

Main benefits.

low voltage shunt trip breaker

Right mounted version suitable for both MCBs and RCDs and left mounted version for MCBs

low voltage shunt trip breaker

Time-saving mounting through the fixed snap-hooks for the right mounted version and through the connection links on the left mounted version

low voltage shunt trip breaker

Combination with auxiliary and signaling contacts as well as with the Motor Operating Devices (MOD) and Auto-Reclosing units (AR)

Main features

  • Pass-through for pin busbars on top and bottom to enable installation with busbar
  • QR code printed on the front of the product to easily access product data
  • Wiring cross sections: 1 wire 0,75...2,5mm², 2 wires max. 2 x 1,5mm²
  • Extended voltage range for A1 version. From 12…60 V AC/DC to 12…110 V AC/DC 

Products and Documentation

  • 2D drawing S3C-A1L S3C-A2L ( en - pdf - Drawing )
  • 2D drawing S3C-A1 S3C-A2 ( en - pdf - Drawing )
  • Technical data sheet S3C ( en - pdf - Data sheet )
  • CSA certificate of S3C shunt trips ( en - pdf - Certificate )
  • UL certification S3C shunt trips ( en - pdf - Certificate )
  • UKCA declaration S3C/S2C shunt trips ( en - pdf - Declaration of conformity )
  • Cross reference S3C shunt trips ( en - xlsx - Reference list )
  • Instruction Manual S3C-A1L, S3C-A2L ( en - pdf - Manual )
  • Instruction Manual S3C-A1, S3C-A2 ( en - pdf - Manual )
  • EU Declaration of Conformity S2C-A1, S2C-A2, S2C-A1L, S2C-A2L, S2C-A1U, S2C-A2U, S2C-A1T, S2C-A2T, S2C-A1TL, S2C-A2TL, S2C-A1TU, S2C-A2TU, S3C-A1, S3C-A2, S3C-A1L, S3C-A2L ( en - pdf - Declaration of conformity )
  • 3D data S3C-AxL ( en - stp - CAD outline drawing )
  • 3D data S3C-Ax ( en - stp - CAD outline drawing )

Submit your inquiry and we will contact you

Quickly find an ABB channel partner

  • Middle East and Africa
  • Asia and Oceania
  • Austria - German
  • Belgium - Dutch | French
  • Bulgaria  - Bulgarian
  • Croatia - Croatian
  • Czech Republic - Czech
  • Denmark - Danish
  • Estonia - Estonian
  • Finland - Finnish
  • France - French
  • Germany - German
  • Greece - Greek
  • Hungary - Hungarian
  • Ireland - English
  • Italy - Italian
  • Latvia - Latvian
  • Lithuania - Lithuanian
  • Luxembourg - French
  • Netherlands - Dutch
  • Norway - Norwegian
  • Poland - Polish
  • Portugal - Portuguese
  • Romania - Romanian
  • Russia - Russian
  • Serbia - Serbian
  • Slovakia - Slovakian
  • Slovenia - Slovenian
  • Spain - Spanish
  • Sweden - Swedish
  • Switzerland - French | German | Italian
  • Turkiye - Turkish
  • United Kingdom - English
  • Argentina - Spanish
  • Aruba - Spanish
  • Bolivia - Spanish
  • Brazil - Portuguese
  • Canada - English | French
  • Chile - Spanish
  • Colombia - Spanish
  • Costa Rica - Spanish
  • Dominican Republic - Spanish
  • Ecuador - Spanish
  • El Salvador - Spanish
  • Guatemala - Spanish
  • Honduras - Spanish
  • Mexico - Spanish
  • Panama - Spanish
  • Peru - Spanish
  • Puerto Rico - Spanish
  • United States of America - English
  • Uruguay - Spanish
  • Algeria - English | French
  • Angola - English | French
  • Bahrain - English | French
  • Botswana - English | French
  • Cameroon - English | French
  • Côte d'Ivoire - English | French
  • Egypt - English | French
  • Ghana - English | French
  • Israel - Hebrew
  • Jordan - English
  • Kenya - English | French
  • Kuwait - English
  • Lebanon - English
  • Madagascar - English | French
  • Mali - English | French
  • Mauritius - English | French
  • Morocco - English | French
  • Namibia - English | French
  • Nigeria - English | French
  • Oman - English
  • Pakistan - English
  • Palestine - English
  • Qatar - English
  • Saudi Arabia - English
  • Senegal - English | French
  • South Africa - English
  • Tanzania - English | French
  • Tunisia - English | French
  • Uganda - English | French
  • United Arab Emirates - English
  • Zambia - English | French
  • Zimbabwe - English | French
  • Australia - English
  • Bangladesh - English
  • China - Chinese | English
  • India - English
  • Indonesia - English
  • Japan - Japanese
  • Kazakhstan - Russian
  • Malaysia - English
  • Mongolia - Mongolian | English
  • New Zealand - English
  • Philippines - English
  • Singapore - English
  • South Korea - Korean
  • Sri Lanka - English
  • Taiwan (Chinese Taipei) - Chinese - Traditional
  • Thailand - English
  • Vietnam - English

abb.com privacy settings

Our website uses cookies which are necessary for running the website and for providing the services you request. We would also like to set the following optional cookies on your device. You can change these settings any time later by clicking "Change cookie settings" at the bottom of any page. For more information, please read our privacy notice.

We collect statistics to understand how many visitors we have, how our visitors interact with the site and how we can improve it. The collected data does not directly identify anyone.

We store choices you have made so that they are remembered across visits in order to provide you a more personalized experience.

Your browsing behavior is tracked across websites by advertising and social network service providers. You may see tailored advertising and content on other websites based on your browsing profile.

Preferences​

Advertising and tracking

Popular links

  • ABB Connect
  • ABB Electrification
  • Where to buy
  • Mission to Zero
  • ABB Ability
  • Supplying to ABB
  • Customer events
  • Investor events
  • Media events

low voltage shunt trip breaker

  • Horizontal terminal
  • Vertical terminal
  • Front terminal
  • Vertical terimnal adapter
  • Front terminal adapter
  • Integrated trip unit (DP3)
  • Modular trip unit
  • General use (WS)
  • Generator use (WM)
  • Special protection (WB)
  • Protective coordination (WF)
  • Ground fault (G1)
  • Earth leakage (E1)
  • 2nd Pre-alarm (AP)
  • Neutral 50% (N5)

100-240V AC/DC without alarm contact (P1)

24-60V DC without alarm contact (P2)

  • 100-240V AC/ 100-125V DC with alarm contact (P3)

24-60V DC with alarm contact (P4)

100-240V DC with alarm contact by Solid State Relay (P5)

  • Trip unit display (DP1)
  • Panel board display (DP2)
  • Extension module (EX1)
  • Making current release switch
  • Temperature alarm
  • Field test device (Y-2005)
  • Test jumper
  • CC-link interface unit
  • Modbus-RTU interface unit
  • Profibus-DP interface unit
  • Motor charging device
  • Closing coil
  • Shunt trip device
  • Under voltage trip device
  • Auxiliary switch
  • Cell switch
  • Shorting NC (b) contact
  • Interphase barrier
  • Safety shutters
  • Terminal cover
  • Mis-insertion preventer
  • Drawout interlock
  • Position lock
  • Push button cover
  • Cylinder lock
  • Castel lock
  • Door interlock
  • Mechanical interlock
  • Condenser trip device
  • Lifting hook
  • Load circuit conductors type
  • Transformer grounding wire type

low voltage shunt trip breaker

Product featurers

low voltage shunt trip breaker

  • Vertical terminal adapter

low voltage shunt trip breaker

100-240V AC/100-125V DC with alarm contact (P3)

low voltage shunt trip breaker

ZCT (Load circuit conductors type)

low voltage shunt trip breaker

ZCT (Transformer grounding wire type)

low voltage shunt trip breaker

  • "AE-SW" is the single series of Mitsubishi Electric's ACB for easy choice of quality products.
  • Rating from 630A to 6300A with three compact frames.
  • Frame1: AE630-SW to AE2000-SWA, Frame2: AE2000-SW to AE4000-SWA, Frame3: AE4000-SW to AE6300-SW
  • Fixed or Drawout mounted with 3 or 4 pole versions are available.
  • Compliance with IEC 60947-2, JIS C 8201-2-1. CCC certification for GB 14048.2.
  • With Third party IEC 60947-2 certification from KEMA for all range of ACB.
  • Various Marine standards Lloyd's Register of Shipping, Bureau Veritas, American Bureau of Shipping and etc.
  • Uniform accessories for every frame size of ACB.
  • Stable switching operation thanks to Double spring switching mechanism. movie
  • Modular trip unit with Protection and Metering based modules for easy upgradability.   movie
  • Color changing LCD backlight on trip unit for easy notification in the event of Pre-alarm and Fault. movie
  • Double multiplication setting on Rated current and Pre-alarm for more precise value setting.
  • Icu = Ics = Icw = Min. 65kA (1sec) / Icw = Min. 50 kA (3sec) for better discrimination with branch circuit breakers.
  • Communication through CC-link, Modbus-RTU and Profibus-DP available for remote control and energy monitoring.
  • Lower watt loss ACB contribute to reducing temperature rise inside panel and waste of energy flow.
  • Zero arc space provides more reliable and safety operation for AE630-SW to AE4000-SWA at 600V AC or less.
  • Reverse connection is available without any limitation.

Connections

low voltage shunt trip breaker

  • Various terminal connections are available based on panel board specifications.
  • The different types of terminal connections between line side and load side are also available. (For AE2000-SWA, AE4000-SWA, AE4000-SW, AE5000-SW and AE6300-SW models, only vertical terminal is available.)
  • Reverse connection is available without any limitation. movie
  • Various terminal connections are available based on panel specifications.

Electronic trip unit

low voltage shunt trip breaker

  • Integrated trip unit with monitoring display for current and harmonics along with Fault memory function.
  • Color changing LCD backlight on trip unit for easy notification in the event of Pre-alarm and Fault.
  • Current level (60/80/100% of rating), Pre-alarm, Overload and Trip cause are indicated with different color of LED.
  • Adjustable Pre-alarm (68%-100% of rated current) and Overload alarm (115% of rated current) as standard.
  • Self-diagnose and Error indication LED for Trip Unit as standard (Self-diagnose on Malfunction of Microprocessor and Hardware, Miswiring related to Trip unit and etc) movie

low voltage shunt trip breaker

  • Modular trip unit with Protection and Metering based modules for easy upgradability as well as communication.
  • Color changing LCD and optional protection units such as Ground fault, Earth leakage, 2nd Pre-alarm are modular.
  • Self-diagnose and Error indication LED for Trip Unit as standard. (Self-diagnose on Malfunction of Microprocessor and Hardware, Miswiring related to Trip unit and etc) movie

Main protection module

low voltage shunt trip breaker

  • Main protection modules are available for most common applications like transformers, cables, motors and generators protection. movie

Optional protection module

low voltage shunt trip breaker

  • Optional protection module for Ground fault, Earth leakage, 2nd Pre-alarm and Neutral pole 50% protection.
  • With these protection based modules, no need to change the whole Trip unit to change the specification. movie

Power supply module

low voltage shunt trip breaker

  • Power supply module is required for the LED indication on Trip unit, Metering and Communication function.
  • Power supply without alarm contact or with 6 alarm contacts are available based on rated voltage.
  • 6 alarm contacts include LTD, STD/INST, Ground fault/Earth leakage/Additional Pre-alarm, Pre-alarm, Temperature alarm, Error on Trip unit. movie

low voltage shunt trip breaker

  • Color changing LCD backlight for Modular trip unit is available.
  • Record 10 trip history inclusive the types of protection cause (LSIGE, Under voltage, Temperature alarm).
  • At the time of trip and alarming, the backlight color automatically change for easy notification. movie

low voltage shunt trip breaker

  • Color changing LCD backlight for Panel board mounted type is also available.

low voltage shunt trip breaker

  • Expansion module is required for metering and display function. movie

low voltage shunt trip breaker

  • VT unit is required to measure voltages, powers, energy, harmonics current. movie

low voltage shunt trip breaker

  • This switch makes Instantaneous operation (INST) ineffective once after the breaker is closed.
  • This is used for expanding the selective combination with branch circuit breakers. movie

low voltage shunt trip breaker

  • Temperature alarm is available to identify the abnormal heat with main contacts of the breaker.
  • The alarm is indicated by LED on Trip unit and it can also output signal in case Power supply module with alarm contacts (P3/P4/P5) is used.
  • It makes it easy to notify the time of maintenance or replacement of the breaker. movie

Test equipment

low voltage shunt trip breaker

  • The operation of Electronic trip unit can be tested with this Field test device (Y-2005). movie

low voltage shunt trip breaker

  • While the breaker taken out of its cradle, the Test jumper enables the breaker to be electrically open and closed.
  • The operating sequence of the breaker also can be checked. movie

Communication

low voltage shunt trip breaker

  • For intelligent energy management, the communication modules connect the breaker to higher level of remote control and energy monitoring in the combination with Mitsubishi Electric products.
  • The communication available with CC-Link, Modbus-RTU or Profibus-DP. movie

low voltage shunt trip breaker

  • For remote control of the breaker via communication system, this Input and output unit is required. With this, it become possible to control the breaker remotely, like open and close operation or Spring charging.
  • This makes it easy to enhance communication for local applications. movie

Remote control

low voltage shunt trip breaker

  • The breaker is remotely charged by the Motor charging device.
  • When the breaker is closed, the double springs inside the breaker are charged automatically. movie

low voltage shunt trip breaker

  • The breaker is remotely closed by the Closing coil.
  • It is one-pulse driven to prevent pumping and burnout of coil as standard. movie

low voltage shunt trip breaker

  • The Shunt trip device turns the breaker opened immediately when the operational voltage is applied.
  • A cut off switch is equipped as standard to prevent burnout of coil as standard. movie

low voltage shunt trip breaker

  • This device automatically open the breaker if the operational voltage is not applied or drops below specific value.
  • This protect electrical equipments against voltage fluctuation and also can be used for remote control of the breaker.
  • There are three types of operating time. Instantaneous (0.2 sec), 0.5 sec and 3.0 sec. movie

Indication contact

low voltage shunt trip breaker

  • OCR alarm is provided with Electrical trip unit as standard.
  • Automatic reset type and Manual reset type are available.
  • For Automatic reset type, alarm is 1 NO contact of short-time operation (30ms), being output when the breaker trip. movie

low voltage shunt trip breaker

  • Auxiliary switches make a signal for the switching (open/closed) status of the breaker. movie

low voltage shunt trip breaker

  • This switches (NO/NC contact) indicate the drawout position (CONNECTED, TEST, and DISCONNECTED) of the breaker.
  • The arbitrary combination up to 4 pieces is available. movie

low voltage shunt trip breaker

  • When drawout ACB from "CONNECT" to "TEST" position, this contact is used to short the auxiliary switch (NC contact). Thus, maintaining the correct sequence of operation of the external control circuit. movie

Safety device

low voltage shunt trip breaker

  • This barrier enhance the interphase insulation between the terminal portions of the breaker, and prevents short-circuit due to conductive inclusion or dust. movie

low voltage shunt trip breaker

  • The Safety shutters cover the cradle side of conductors and prevent contact with them when ACB is drawn out.
  • The shutter lock is also available as an option. movie

low voltage shunt trip breaker

  • The Terminal cover prevents from careless touching to the live part of control terminals.
  • Protection degree is IP20. movie

low voltage shunt trip breaker

  • Mis-insertion preventer allow only specified circuit breakers can be inserted into the cradle.
  • Five patterns of Mis-insertion preventers are available. (Not available for AE4000-SW~AE6300-SW.) movie

Locking device

low voltage shunt trip breaker

  • When the breaker is ON, the drawout handle cannot be inserted into the breaker.
  • The insertion and drawout operation of the breaker cannot be done unless the OFF button is pressed. movie

low voltage shunt trip breaker

  • During insertion and drawout operation, the drawout mechanism of the breaker is automatically locked at "TEST" and "Connect" position as standard.
  • Once the lock plate is pushed in, the lock is released and the operation can be continued. movie

low voltage shunt trip breaker

  • The Push button cover prevents unintentional manual switching operation by the push button.
  • The Push button cover can be locked by the padlock. movie

low voltage shunt trip breaker

  • The breaker can be locked in the open position with the Cylinder lock.
  • It provide reliable protection for personal during maintenance activities. Also, it can be used for interlocking two or more breakers which only allows the key to be removed when the breaker is in the open position. movie

low voltage shunt trip breaker

  • The breaker can be locked in the open position with the Castel lock.
  • In this lock, only the key lock set-up for Castel lock is available and the key must be supplied by the customers. movie

low voltage shunt trip breaker

  • With Door interlock, the panel door cannot be opened unless the breaker is in open position.
  • A wire type mechanical interlock allows flexibility of the circuit breakers' position inside the panel. movie

low voltage shunt trip breaker

  • Mechanical interlock is the device to prevent parallel closing operation of 2 or 3 units of breakers.
  • It assure the interlock mechanically between the breakers. movie

Other accessories

low voltage shunt trip breaker

  • The Door frame improves the appearance. It is installed after cutting out the panel door. movie

low voltage shunt trip breaker

  • Dust cover prevents the dust or water entering into the panel board when ACB is used with the front cut panel.
  • Protection degree is IP54. movie

low voltage shunt trip breaker

  • The open/close operations of the breaker can be recorded by a 5 digit counter. movie

low voltage shunt trip breaker

  • Even if the power supply fails, the breaker can be electrically opened in the combination with the Condenser trip device and the Shunt trip device within a definite time. movie

low voltage shunt trip breaker

  • Lifting hook is the metal fitting to suspend the breaker main body when it is removed from the cradle. movie

low voltage shunt trip breaker

  • For 3 pole circuit breakers used in 3 phase 4 wire systems, the Neutral CT is used for ground fault protection and over current protection of Neutral phase. movie

low voltage shunt trip breaker

  • ZCT is used to detect earth leakage current in the combination with earth leakage protection module (E1).
  • ZCT of ACB's load circuit conductors type or Transformer grounding wire type are available. movie
  • Get custom product tools and services
  • Access training
  • Manage support cases
  • Create and manage your orders (authorised partners only)

Welcome to the Schneider Electric Website

Search FAQs

What is the difference between a shunt and undervoltage trip for the breaker, released for: schneider electric australia.

Articles that might be helpful

Discuss this topic with experts

Start here!

Find answers now. Search for a solution on your own, or connect with one of our experts.

Contact Support

Reach out to our customer support team to receive more information, technical support, assistance with complaints and more.

Where to buy?

Easily find the nearest Schneider Electric distributor in your location.

Search topic-related frequently asked questions to find answers you need.

Contact Sales

Start your sales enquiry online and an expert will connect with you.

Breaker King

  • CLEARANCE ITEMS
  • Safety Switches/Disconnects Double Throw Transfer Switches Nema 1 Indoor Nema 12 Dust and Oil Resistant Nema 3R Rainproof Nema 12/4X Corrosion Resistant Nema 3R A/C Pull-Outs
  • Busway Plug-in Devices Cutler-Hammer/Eaton Federal Pacific Electric General Electric I-T-E/Gould/Bulldog Siemens Square D/Schneider Westinghouse
  • Panelboard Switches Cutler-Hammer/Eaton Federal Pacific Electric General Electric Siemens/I-T-E Square D/Schneider Westinghouse
  • Fuses and Accessories Edison Base Mini-Breakers RK5 ECNR/ECSR RK5 FLSR BLOWN FUSE INDICATOR RK5 Fuse Reducers Class L Edison Base Plug Fuses Class J CF CUBEFuse Cross Reference
  • Circuit Breakers UL1077 DIN Mount Petroleum Market Plug-in & Residential New Commercial/Ind'l New Commercial/Ind'l Used Obsolete Ind'l Used Breaker Mounting Kits Breaker Enclosures Handle Locks and Ties Filler Blanks Obsolete & Used Residential Breaker Testing Surge Arrestors Ghosts of the Past Breaker Reset
  • Spa and Hot Tub Panels
  • Loadcenters & Accessories Sqr D Loadcenters Siemens Loadcenters Loadcenter Accessories
  • Motor Controls and Parts Lighting Contactors Definite Purpose Contactors Manual Motor Starters Local Control Stations Push Buttons/Contact Blocks Indicating Lights FVNR Magnetic Starters Replacement Contact Kits Replacement Coils
  • Plastic Molders Supplies Mold Releases Mold Cleaners Rust Preventatives Ejector Pin Grease Purging Compounds Food Grade Medical Grade Maintenance Compounds
  • Low-Voltage Lighting Parts Touchplate General Electric
  • RV/Campground Accessories RV Plug Adapters RV Panel Breakers Breaker Mounting Bases
  • Obsolete Breaker Guide

US Constitution

Home  |  Circuit Breakers  |  Commercial/Ind'l New  |  Siemens  |  BQD Shunt Trip

BQD Shunt Trip

BQD Shunt Trip

  • Model: BQD35000S01
  • Shipping Weight: 4lbs
  • Manufactured by: Siemens

IMAGES

  1. 20A Shunt Trip THQB1120ST1 General Electric 1-Pole Breaker

    low voltage shunt trip breaker

  2. Shunt Trip Breaker Wiring Diagram Explanation

    low voltage shunt trip breaker

  3. THQB32050ST1 GE Shunt Trip Circuit Breaker

    low voltage shunt trip breaker

  4. EDB34045SA 120V Shunt Trip SQUARE D SCHNEIDER ELECTRIC Bolt-on EDB

    low voltage shunt trip breaker

  5. 220V Shunt Trip For 3 & 4P MCCB 16 to 250A

    low voltage shunt trip breaker

  6. What Is a Shunt Trip Breaker? Guide to Electrical Circuit Protection

    low voltage shunt trip breaker

VIDEO

  1. Shunt Trip Simulation Test

  2. !! shunt trip unit وفيما تستخدم وكيفية تركيبها !! MCCB Shunt Trip Unit

  3. SHUNT TRIP breaker para ELEVADORES ✨️

  4. How to install Shunt Closing Release for E1.2 ACB

  5. EasyPact MVS How To Install Accessory Urdu/Hindi

  6. eaton shunt trip breaker wiring diagram

COMMENTS

  1. PDF Shunt trip in Magnum low voltage circuit breakers

    The shunt trip opens the circuit breaker when its coil is energized by a voltage input. The intermit-tent shunt trip is limited to intermittent duty and requires the included shunt trip cut-off switch. When replacing a standard shunt trip, both the shunt trip and the cut-off switch must be replaced. The continuous duty shunt trip does not require a

  2. What is a Shunt Trip Breaker and How Does It Work?

    The shunt trip breaker is a combination of the shunt trip accessory and the main circuit breaker. This installs on the main breaker to add protection to your electrical system. This adds security to your electrical system as it manually or automatically cuts the electric supply in your circuit. This accessory can help prevent short circuits and ...

  3. What Is A Shunt Trip Breaker & How Does It Work? Detailed Guide

    The shunt trip breaker is a combination of a shunt trip accessory and a main circuit breaker. it connects to the main breaker for the protection of the electrical system. it also added security to the system since it manually or automatically cut the supply in the circuit. In this post, we will discuss the all details shunt trip breaker and ...

  4. How Does a Shunt Trip Breaker Work?

    A shunt trip breaker is a specialized circuit breaker that is designed to remotely shut off power to a circuit in emergency situations, such as a fire or security breach. These breakers are commonly used in commercial and industrial buildings, as well as other facilities where safety is a top priority. In this article, we'll explore this type ...

  5. GE SHUNT TRIP MANUAL Pdf Download

    2. Catalog numbers and voltages for the Shunt Trip with Lockout. Operation. Apply control voltage to terminals. terminal strip on the right side of the breaker to trip. the circuit breaker. The Shunt Trip will. circuit breaker to trip when. greater than 75% o f the rated de voltage or 55% of the.

  6. PDF Eaton s heavy duty safety switches with shunt trip capability remote

    2 Technical Data TD008003EN Effective September 2014 Shunt trip safety switch EATON www.eaton.com Standards compliance • UL® 98 file number E5239 (600 Vac maximum) • CSA® C22.2 No. 4 file number LL69743 (600 Vac maximum) • UL 98B—contact factory for specific file information (1000 Vdc maximum) • UL 50 • NEMA KS-1 Table 1.

  7. Power Break* II insulated case circuit breakers

    Power Break® II Mechanical Interlock for Stationary Breakers, 800-2000 A Frames - GEH6286 ( en - pdf - Instruction ) Power Break® II Undervoltage Release - GEH6285 ( en - pdf - Instruction ) Power Break® II Shunt Trip and Shunt Trip with Lockout - GEH6284 ( en - pdf - Instruction ) Power Break® II Remote Close - GEH6283 ( en - pdf ...

  8. Shunt Trip

    Aug 21, 2009. #3. Shunt trip breakers are just like normal breakers but they can be turned off electrically. There is a mechanism built into them that turns them off if power is applied to the mechanism. Shunt trip breakers usually require an extra 'space' in the panel for the mechanism.

  9. How does a shunt trip work to trip a circuit breaker?

    Circuit Breakers. Resolution: A shunt trip device is an optional accessory in a circuit breaker that mechanically trips the breaker when power is applied to the shunt trip terminals. The power for the shunt trip does not come from within the breaker, so it must be supplied from an external source. Released for: Schneider Electric USA.

  10. Shunt Trip

    Siemens B12000S01 Siemens Low Voltage Molded Case Circuit Breaker, 20A, Single-Pole, 120V, 10kAIC. ... Siemens B230H00S01 Shunt Trip Breaker, 30A, 120V, 2-Pole. Pack of 1 Unit; additional within CES Network Additional stock within The CES Network for ship-to-store or delivery. Confirm at checkout.

  11. PDF Instructions for Low Voltage Power Circuit Breakers Types DS and DSL

    This instruction book is expressly intended to cover the installation, operation and maintenance of Low Voltage Power Circuit Breakers, Types DS and DSL. For application information, consult your nearest Eaton sales office, see Eaton Descriptive Bulletin 32-850, or appropriate ANSI Standards. NOTE: This manual covers both Pre and Post 1988 ...

  12. Power source for shunt trip circuit

    With a shunt trip circuit, three things must happen to trip the breaker. 1) fault detection circuit works, 2) shunt trip power source works, then 3) shunt trip coil works. We've switched over to Undervoltage Release mechanisms because of problems with #2. The UV coil trips the breaker when power is lost. So now you're down to two things.

  13. Shunt trips

    Shunt trips. Shunt trips are used to remote opening of the device when a voltage is applied. Shunt trips use a coil like MCBs for tripping. To trip a shunt it is necessary to choose the right voltage and make sure the corresponding Ibmax is provided by the power supply used.

  14. AE-SW

    Trip unit display (DP1) Panel board display (DP2) Extension module (EX1) VT unit. Making current release switch. Temperature alarm. Interphase barrier. Safety shutters. Terminal cover. Mis-insertion preventer. CC-link interface unit. Modbus-RTU interface unit. Profibus-DP interface unit. I/O unit. Motor charging device. Closing coil. Shunt trip ...

  15. QBHW Bolt-in SHUNT TRIP (120V) [QBHW1020S] : Breaker King

    Breaker King QBHW Bolt-in SHUNT TRIP (120V) [QBHW1020S] - Square D 1P 20A 120V SHUNT TRIP circuit breaker. 10KAIC. Requires two panel spaces. Toggle navigation. Home; Terms; ... Low-Voltage Lighting Parts. Touchplate General Electric. RV/Campground Accessories. RV Plug Adapters RV Panel Breakers Breaker Mounting Bases.

  16. What is the difference between a shunt and undervoltage trip for the

    the release provokes opening of the circuit breaker. MX shunt release The MX release opens the circuit breaker via an impulse-type (u 20 ms) or maintained order. Opening conditions When the MX release is supplied, it automatically opens the circuit breaker. Opening is ensured for a voltage U u 0.7 x Un. Released for: Schneider Electric Australia

  17. PDF Magnum PXR and Power Defense SB low voltage power circuit breakers

    Overview of the Magnum PXR and PD-SB low voltage circuit breakers 1 MANM PX PDS PDC DE PA013006EN May 2023 www.eaton.com Magnum PXR and PD-SB breaker product family continued ... 2nd shunt trip (ST) N = None A = Inst. UVR (110-127 Vac) R = Inst. UVR (208-240 Vac) X = Inst. UVR (380-415 Vac) J = Inst. UVR (480 Vac)

  18. BQD Shunt Trip [BQD35000S01] : Breaker King

    Breaker King BQD Shunt Trip [BQD35000S01] - Siemens 3P 50A 480V Molded Case Circuit Breaker with Side Mounted CQDST120 Shunt Trip. 14KAIC. Requires 4 Panel Spaces. ... Low-Voltage Lighting Parts. Touchplate General Electric. RV/Campground Accessories. RV Plug Adapters RV Panel Breakers Breaker Mounting Bases.

  19. PDF QF(13)

    QF13-SERIES-DAT REV.G JUNE 2024 2405025 Data Sheet Page 6 of 8 low voltage Time Delay Curves QF(13) - Series Miniature Circuit Breakers * The published time delay curves are generated at 30oC ambient temperature with the circuit breaker mounted in the up-right position.The "must hold", "must trip"