Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual

  • Trane Manuals
  • Air Conditioner
  • Voyager YS 150-300
  • Installation, operation and maintenance manual

Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual

  • page of 52 Go / 52

Table of Contents

Troubleshooting.

  • Overview of Manual

Model Number Description

  • Model Number Notes

General Information

  • Unit Description
  • System Input Devices & Functions
  • Phase Monitor
  • Unit Inspection
  • Unit Clearances

Unit Dimensions

Unit weights, installation.

  • Factory Installed Economizer
  • Main Electrical Power Requirements
  • Filter Installation
  • Electric Heat Requirements
  • Field Installed Power Wiring
  • Condensate Drain Configuration
  • Main Unit Power
  • Controls Using 24 Vac
  • Voltage Imbalance
  • Compressor Crankcase Heaters
  • Reliatel Controls

Factory-Mounted Unit Options

  • Circuit Breaker (FIYUCB) & Unit Disconnect (FIYUDC)
  • Powered and Unpowered Convenience
  • Return Air Smoke Detector
  • Through the Base Gas Utility Option
  • Verifying Proper Air Flow (Units with Belt Drive Indoor Fan)
  • Economizer Start-Up
  • Compressor Start-Up
  • Dehumidification Option
  • Heating Start-Up
  • Variable Air Volume Applications (Multi-Zone, Traditional VAV)
  • Vhr Relay Output
  • Final System Set up

Maintenance

  • Fan Belt Adjustment-Belt Drive Units
  • Monthly Maintenance
  • Final Process
  • Reliatel Control
  • System Status Checkout Procedure
  • Resetting Cooling and Heating Lockouts
  • Zone Temperature Sensor (ZTS) Service Indicator
  • Zone Temperature Sensor (ZTS) Test
  • Programmable & Digital Zone Sensor Test

Wiring Diagrams

Advertisement

Quick Links

  • 1 Model Number Description
  • 2 Model Number Notes
  • 3 Unit Description
  • 4 Unit Dimensions
  • 5 Wiring Diagrams
  • Download this manual

Related Manuals for Trane Voyager YS 150–300

Air Conditioner Trane Voyager YS 150F Owner's Manual

Summary of Contents for Trane Voyager YS 150–300

  • Page 1 Installation, Operation, and Maintenance Packaged Rooftop Air Conditioners Voyager™ Gas/ Electric – 12½ – 25 Tons, 60/50Hz Model Number: YS*150–300 YH*150-300 SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air- conditioning equipment can be hazardous and requires specific knowledge and training.
  • Page 2 Carbon (HCFCs). Not all refrigerants containing these WARNING compounds have the same potential impact to the Proper Field Wiring and Grounding environment. Trane advocates the responsible handling of Required! all refrigerants-including industry replacements for CFCs such as HCFCs and HFCs.

Page 3: Overview Of Manual

Page 4: table of contents, page 5: model number description, page 6: model number notes, page 7: general information, page 8: phase monitor, page 9: sensors.

  • Page 10 General Information Thermostat (BAYSTAT151) Failure to follow these instructions will prevent the smoke detector from performing its design function. This thermostat is a single-stage 1 heat/1 cool, auto- changeover digital display thermostat. It is a non- Unit Model Minimum Allowable Airflow with programmable, wall-mounted thermostat.

Page 11: Unit Inspection

Page 12: unit dimensions.

  • Page 13 Unit Dimensions Figure 2. Unit dimensional data for 12½ tons standard efficiency units 1273 mm (50 1/8”) 25 mm (1”) 168 mm (6 5/8”) DOWNFLOW CONDENSATE DRAIN CONN 25 mm (1”) NPT 745 mm 651 mm (29 5/16”) (25 5/8”) 152 mm (6”) 1453 mm...
  • Page 14 Unit Dimensions Figure 4. Horizontal duct dimensional data 12½ tons standard efficiency units Figure 5. Unit dimensional data 15–25 tons standard efficiency units 1372 mm (54”) 25 mm (1”) 173 mm (6 13/16”) DOWNFLOW CONDENSATE DRAIN CONN 25 mm (1”) NPT 679 mm (26 3/4”) 151 mm...
  • Page 15 Unit Dimensions Figure 6. Unit dimensional data 12½ ton high efficiency units 1372 mm (54”) 25 mm (1”) DOWNFLOW CONDENSATE DRAIN CONN 25 mm (1”) NPT 679 mm (26 3/4”) 152 mm (6”) 1643 mm (64 11/16”) GAS CONNECTION (SEE NOTE 1) 843 mm (33 3/16”) 3091 mm...
  • Page 16 Unit Dimensions Figure 8. Unit dimensional data 15–25 tons standard efficiency units, 12½–25 tons high efficiency units Figure 9. Horizontal duct dimensional data 15–25 tons standard efficiency units, 12½–25 tons high efficiency units RT-SVX26K-EN...

Page 17: Unit Weights

Page 18: rigging, page 19: installation, page 20: factory installed economizer, page 21: main unit power, page 22: controls using 24 vac.

  • Page 23 Installation Figure 16. ReliaTel relative humidity sensor (dehumidification option) Figure 17. ReliaTel humidistat (dehumidification option) RT-SVX26K-EN...
  • Page 24 Installation Figure 18. Typical field wiring diagrams for optional controls (ReliaTel only) BAYSENS075* BAYSENS075* BAYSENS108* BAYSENS106* BAYSENS110* BAYSENS119* BAYSENS073* BAYSENS074* BAYSENS075* ASYSTAT669A OPTIONAL REMOTE SENSOR RT-SVX26K-EN...

Page 25: Space Temperature Averaging

  • Page 26 Installation Table 6. Space temperature averaging examples RT-SVX26K-EN...

Page 27: Voltage Imbalance

Page 28: compressor crankcase heaters, page 29: reliatel controls, page 30: factory-mounted unit options, page 31: powered and unpowered convenience, page 32: return air smoke detector.

  • Page 33 Factory-Mounted Unit Options Figure 25. Return air smoke detector for downflow units TWO PIECE HOOD PLASTIC ELBOW METAL INTAKE TUBE SMOKE DETECTOR COPPER TUBE (FACTORY INSTALLED) VINYL TUBES (7-3/4 INCHES LONG) VINYL TUBES (2 INCHES LONG) METAL EXHAUST TUBE (16.34 INCHES LONG) TUBES INSTALL FROM BOTTOM, TOP DOES NOT NEED TO BE REMOVED FROM SMOKE DETECTOR...
  • Page 34 Factory-Mounted Unit Options In order for the return air smoke detector to properly sense Figure 26. Smoke detector wiring scheme smoke in the return air stream, the air velocity entering the unit must be between 500 and 4000 feet per minute. Most models of equipment covered by this instruction will develop an airflow velocity that falls within these limits over the entire airflow range specified in the evaporator...

Page 35: Through The Base Gas Utility Option

Page 36: pre start, page 37: start up, page 38: dehumidification option, page 39: vhr relay output, page 40: final system set up, page 41: maintenance, page 42: monthly maintenance, page 43: final process, page 44: troubleshooting, page 45: resetting cooling and heating lockouts, page 46: zone temperature sensor (zts) service indicator, page 47: programmable & digital zone sensor test.

  • Page 48 Troubleshooting WARNING Hazardous Voltage! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. 1.

Page 49: Wiring Diagrams

  • Page 50 Wiring Diagrams Table 23. Wiring diagrams for units with High Short Circuit Rating (SCCR) Type of Schematic Diagram airflow Type Voltage Number Description 208-230, 2313-1579 YS*180-300, YH*150-300, 2-Stage Gas Heat 460, 575 Power 2313-1580 YS*180-300, YH*150-300, Modulating Gas Heat (60 Hz) 2313-1584 YS*180-300, YH*150-300, 2-Stage Gas Heat 208-230, 460, 575...

Page 51: Warranty

  • Page 52 The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2014 Trane All rights reserved We are committed to using environmentally RT-SVX26K-EN 27 May 2014 conscious print practices that reduce waste.

This manual is also suitable for:

Rename the bookmark, delete bookmark, delete from my manuals, upload manual.

IMAGES

  1. Voyager™ II Rooftop Units

    trane voyager product data

  2. Trane Voyager 12.5 to 25 Tons Catalogue

    trane voyager product data

  3. Trane® Voyager 12.5 to 50 Ton Commercial HVAC Rooftop Units

    trane voyager product data

  4. Trane Voyager 12 5 To 25 Tons Catalogue 1/2 20 60 Hz

    trane voyager product data

  5. Trane® Voyager 12.5 to 50 Ton Commercial HVAC Rooftop Units

    trane voyager product data

  6. Trane Voyager TS, Voyager YS, Voyager WS Catalogue

    trane voyager product data

VIDEO

  1. Voyager 3_1_10.wmv

  2. 1992 Trane Voyager 20 Ton Startup

  3. Trane Voyager commercial gas pack

  4. New Trane EU-ANZ Website

  5. Commercial Trane RTU

  6. Trane RTRM Construction Mode / 68 Heat

COMMENTS

  1. PDF Product Catalog

    Trane delivers with Voyager. Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer-aided run testing, and Integr ated Comfort™ Systems. So, whether you're the contractor, the engineer, or the owner, you can be certain Voyager products are built to meet your needs. Trademarks

  2. Voyager® 3 Rooftop Units

    Voyager 3 units are capable of integrating into building automation and control systems for optimization, monitoring and data analysis. New models are equipped with the Symbio® 700 controller for improved usability and automated optimization. Symbio's intuitive user interface displays system alarms, diagnostics and resolutions.

  3. PDF Voyager™ II Rooftop Units

    tion and diagnostic displayThe unit shall be equipped with a 5' high resolution col. r touch screen LCD display. The display allows you to view data and make operati. nal changes on the rooftop. Display sh. ts (3 custom, 12 standard),12 different graphs (4 custom, 8 standard) View and reset historic.

  4. TRANE VOYAGER MANUAL Pdf Download

    View and Download Trane Voyager manual online. Product. Voyager air conditioner pdf manual download. Sign In Upload. Download Table of Contents Contents. Add to my manuals. Delete from my manuals. Share. ... 4 Ton Data Standard Efficiency Table 9-1 General Data 3 Ton Downflow Units 4 Ton Downflow and Horizontal Units YCD036C1 YCD036C3, C4 YC ...

  5. PDF Voyager™ I Rooftop Units

    points. For added water integrity, Voyager has a raised 30 mm lip around the supply and return of the downflow units to prevent water from blowing into the ductwork. Quality And Reliability † The fan and idler arm assembly designs have been tested to over 300,000 cycles each. † All of Voyager's designs were rigorously rain tested at

  6. Voyager

    Voyager 2 - 12.5 - 25 Tons Voyager 3 - 27.5 - 50 Tons . We know time is money. You can have your Voyager unit in two to three weeks - the fastest delivery in the industry - to help keep projects on track and get job sites up and running quickly. Choose from Voyager 2 or Voyager 3 models to meet the needs of a broad range of small, medium to large commercial buildings.

  7. PDF Quick Reference Guide Voyager™ 12.5 to 25 Tons Packaged Rooftop Units

    4 5 3 Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car ®, Ingersoll Rand , Thermo King and Trane ®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and

  8. PDF Installation, Operation, and Maintenance

    Voyager™ - Cooling, Gas/Electric 12.5 to 25 Tons, 60/50Hz February 2017 RT-SVX26P-EN ... Trane advocates the responsible handling of ... All products are identified by a multiple character model number that precisely identifies a particular type of unit. An explanation of the

  9. PDF Product Catalog Packaged Rooftop Air Conditioners Voyager™ with eFlex

    Trane delivers with Voyager with eFlex™ technology. Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer-aided run testing, and Integr ated Comfort™ Systems. So, whether you're the contractor, the engineer, or the owner, you can be certain Voyager products are built to meet your needs.

  10. PDF Voyager™ III Rooftop Units

    † The Trane Voyager Rooftop has, by far, the best COP in its class. All performances are Eurovent certified which provides the assurance of accurate performance and common comparison criteria. Rigorous Testing † All of Voyager's designs were rigorously rain tested at the factory to ensure water integrity. † Rigging tests include lifting a ...

  11. PDF Voyager

    Voyager is one of the most complete lines of packaged units on the market today. Trane Voyager 12½- to 25-ton units are built to provide not only ultimate indoor comfort, but also comfort in knowing that our packaged units are easy to install and maintain. Voyager units have the highest standards in quality and reliability, ease

  12. PDF Precedent and Voyager Light Commercial Rooftop Units

    Trane solutions optimize indoor environments with a broad portfolio of energy efficient heating, ventilation and air conditioning systems, building and contracting services, parts support and advanced control. For more information, visit ingersollrand.com or trane.com. Reporters may contact: Liz Soltoff, [email protected], 732.652.6952.

  13. TRANE VOYAGER TC* USER MANUAL Pdf Download

    View and Download Trane Voyager TC* user manual online. Packaged Cooling & Gas/Electric Rooftops 12 1/2-25 Tons — 60 Hz. Voyager TC* air conditioner pdf manual download. ... Page 108 Trane A business of American Standard Companies www.trane.com Trane has a policy of continuous product and product data improvement and reserves the right to ...

  14. PDF Quick Reference Guide Voyager™ 12½-25 Ton Packaged Rooftop Units

    Voyager 12 1/2 - 25 Ton Packaged Rooftop Units Cooling and Gas/Electric - Models T/YSD, T/YSH, T/YHD, T/YHH / Quick Reference Guide Author: TCS- Unitary Subject: Voyager 12.5-25 Ton Cooling & Gas/Electric Keywords: Voyager, cooling, gas/electric, Quick Reference Guide, RT-PRC038G-EN, Low Leak Economizer Created Date: 1/12/2006 9:15:33 AM

  15. PDF Packaged Gas/Electric Rooftop Units

    Trane delivers with Voyager. Voyager features cutting edge technologies: reliable compressors, Trane engineered ReliaTel controls, computer-aided run testing, and Integrated Comfort™ Systems. So, whether you're the contractor, the engineer, or the owner you can be certain Voyager Products are built to meet your needs. s It'Hard To Stop A ...

  16. Trane Voyager YC* Manuals

    Trane Voyager YC* Pdf User Manuals. View online or download Trane Voyager YC* User Manual. Sign In Upload. Manuals; ... General Data — 17,5-20 Tons. 18. General Data — 25 Tons. 20. General Data — 17,5 20, 25 Tons ... Related Products. Trane Voyager YSD/YSH 090

  17. Packaged Rooftop Air Conditioners Voyager Cooling and Gas ...

    Voyager continues to provide the highest standards in quality and reliability, comfort, ease of service, and the performance of Trane light commercial products. Trane customers demand products that provid e exceptional reliability, meet stringent performance requirements, and are competitively priced. Trane delivers with Voyager.

  18. TRANE VOYAGER YS 150-300 INSTALLATION, OPERATION AND ...

    View and Download Trane Voyager YS 150-300 installation, operation and maintenance manual online. Packaged Rooftop - Gas/ Electric 121/2 - 25 Tons, 60/50Hz Air Conditioners. ... Page 52 The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice ...

  19. Voyager 3 w/ Symbio 700 User Guide

    Voyager 3 w/ Symbio 700 User Guide. and protection of the equipment. It offers equipment and control configurations that can be used with. light commercial packaged equipment. This control system consists of the Symbio 700 main controller. and up to four option modules used to provide optional functional operation. A system may or may not.

  20. Voyager™ 25 Tons Two-Stage Commercial Packaged Air Conditioner

    R-410A. Tonnage: 25 Ton. UL Listed: Yes. Volts: 460V. 0. Find the Trane 25 Tons Two-Stage Commercial Packaged Air Conditioner at Ferguson online for delivery or pickup at a Ferguson store near you.

  21. PDF Product Data

    Product Data. 2 22-1936-1F-EN Features and Benefits • Communicating or 24 V control • Painted metal cabinet with captured foil face insulation ... Outdoor Unit Product Data Guides for performance data. (b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76) (c) Remote filter required. Product Specifications. 22-1936-1F-EN 5 Heater Pressure Drop ...

  22. How does a 25 ton Voyager 2 (with 4 stages of cooling) operate ...

    WARNING: Information in this article is intended for use by individuals possessing adequate backgrounds of electrical and mechanical experience and who comply with all federal, state, and local laws, rules, orders, or regulations related to the installation, service, or repair of a heating or central air conditioning product.

  23. Voyager III

    The Voyager III IOM, RT-SVX34M-EN has instructions (pgs. 50-55) on how to set the Outside Damper position or Outside Airflow setpoint for Constant Volume (CV), Multi-zone VAV (MZVAV) and/or SZVAV units with or without the Demand Control Ventilation option. The problem that most techs run into 99% of the time is that the Outside Damper position ...